. Lets see what we can do If flame is sensed with the gas valve off the control will go into lockout. Relays are usually small cubes, about 1 square, sometimes black, sometimes clear, mounted on a circuit board. Perhaps it could be flow related, if the pump is cavitating or starved for water like if you only have 3/4 or 1 pipes (?). All the leds remain off and the display shows the salt concentration 2900. Also check the pump basket, and possibly the pump impeller may be clogged, but Id first clean the filter. Replace with the exact same MFD number printed on the capacitor. The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. I changed the sand and it is still occurring. Then, take a look at the capacitor, located at 9 oclock. Replace with the exact same MFD number capacitor if defective (they can be tested) the capacitor is the battery that starts the motor. 2) loose pipe coming into the pump (no sealant, or overheated and slightly shrunk), 3) Loose valve lids or o-rings, air-leaky valves in front of the pump (main drain, skimmer). It has been in operation since mid May without and incident before yesterday. News Reporter Reveals On Live TV That Shes Been Secretly Recording Dec 14, 2021. I have replaced the Aqua Rite printed circuit board and the T-Cell-9. Disconnected the chlorination device, and direct connected it eliminating that. An electric motor shop local to you could test them, perhaps for free or low cost. In my area, the pool gets opened mid May and closed mid September, and runs around 8 hours a day. If the filter was a problem, you may notice higher than normal filter pressure (compared to the old pump). While it is normal for an appliance plug to become warm, it is abnormal for such a plug to get hot. Good luck ~, Hi, I just replaced my 3/4 Hayward pump with a 1hp. Thanks! Since you didnt say it trips a breaker, its probably not a short or ground-out of power, although it still could be, typically a wire touching metal other than the terminals on both end of the wire. Tried recalibration and no change. I have a Hayward Self Priming Super Pump Model # C48J2N131B1. What can I do? Or does the breaker need a reset? Question, if I can determine which return pipe is broke could I just block off that return and bypass it. Hi, I changed my Sta Rite motor, it was 10 years old and did not start anylonger, with a brand new one. You could also check incoming voltage, and wire connections, as fluctuating current can cause an overheated motor, but if its very old, it may just be on its way out, sorry to say at which point you could replace just the motor and shaft seal, or the entire pump. hi I followed the set up directions on my new sp1580lx pump and it keeps tripping the breaker. I have chalked all the connections and lubricated the basket seal. 20amp fuse is not blown. If your cell looks like 4B, follow the instructions below for cleaning your cell. If your sweeper has a booster pump, could be a problem with a clogged impeller, or air leak into the pump, or some other pump issue. Most Common areas include the pump lid (must be very tight, with lubed lid o-ring), and the threaded pipe that comes into the FRONT of the pump (must be very tight and sealed if loose, use Pool Putty to fix, or replace the fitting) the effluent or exit pipe fitting leaking will not draw air, that is on the pressure side not the suction side. You can buy replacement drives I believe, that may be the (expensive) cure for the problem. Got a new motor, it made humming noise since day on,if i help it spin it works so I changed the capacitor and still the same, humming and if I help it to spin it goes fine, any suggestions? What do I need to replace the seal plate, the diffuser, the pump housing? Thanks, Steve DeGray. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. LibriVox About. Turned it off and then tried it again and it hummed for a few and the something glowed red and then stopped humming. . Thanks Davy for your quick reply. Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell. Mark, if you can hear the motor winding up and down, then it could be the cord. Also could be a loose stationary switch (motor rear, 6 oclock) or a loose centrifugal switch (motor rear, dead center). Hi I have a variable speed ecostar and am now having the drive error, drive stalled. For a better experience, please enable JavaScript in your browser before proceeding. Fans of space opera and world-building fantasies will find this first book in the series compelling, concluding with a powerful vision of world-changing gods and attempts to free Eden from its curse that conclude in a cliffhanger for future books to explore. They do not seem to have enough stooch even though they are rated at 1HP like my original motor. Still same though nothing being sucked through basket and minor trickle back out into pool. By morning all the dead algae filters back into the pool and it take about 4 days to clear. I have a 2 HP Hayward two speed pump that is on its second season. The pump is a Hayward Superpump SP1600X with a UST1102 motor. The problem lies, where the power dies as they say. Step 4: If none of the previous steps solved the problem, replace your flow switch. IF so, replace the fitting, or pack pool putty or silicone around the fitting, and leave it running for 24 hours, until the sealant sets up hard. Tested the switch on and off and it works as expected. Any insight would be helpful. Anything I can do on my own to fix this? It could also be the wiring from breaker to timer, or timer to pump, or just breaker to pump, if there is no timer or other switch (and if there is no other switch, the breaker is likely just worn out from overuse). Checked everything still doesnt work . Third possibility is just that the pump capacitor is bad, if the motor wont turn over, wont spin. What you have to do is drain the filter and remove all those tiny bolts, and pull out the entire nest assembly. I put a new power cord socket in the water proof box, which feeds power to the pump, I shined up the power cord plug pins), (power cord is about 2.5 ft of 12 Ga, not wet, not laying on the ground) Grids not aligned properly, thus not pushed fully up into manifold HI Mike, the seal and the motor may be separate issues or they may be related. A leaking shaft seal should not cause your filter pressure to decrease. Just be sure to buy the correct seal for your make/model pump, for the Powerflo Matrix pump, thats here: https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c SPX1250XZ2C. Motors are hot normally, 140 degrees or so, but if it shuts off and then resets and turns on again after 15-20 mins, it could be overheating, from voltage problems, loose connections, motor board, switch or capacitor wiring problems, or internal winding shorts. Is the GFCI test button tripped? so.it shut off again. I backflushed the filter and pump would loose almost all water in basket. Fox example, a 1 hp Whisperflo creates twice as much flow as a 1 hp Superpump. and loosing its prime . Hi there, I made the very unfortunate decision to rent my home to a friend. You could use a small plug-in pump timer that would allow you to not unplug, just flip the switch to off. We tried opening the pool today when we plugged in the Hayward filter it keeps blowing the circuit breaker. Armstrong Human Resource Management 13th Edition Pdf, My Hayward Pump Super shuts off and then starts then shuts off and then starts again. . So in actuality the pump is only being used 4 months a year for 8 hours a day. IF its a broken off grease cap, tap in a sharp screwdriver into where it threads in, to get some bite, and then slowly and firmly back out the broken off threaded connector, turning CCW, then replace with a new Grease Cap, or a 1/8 threaded plug. That is the black cylinder located in the rear of the motor, at 9 oclock. Hi Nancy, Heat Sinks are designed to absorb the heat from the motor, and dissipate it safely. Hi David, impellers that have signs of wear are usually operating without a problem. If you have a time clock or light switch in addition to the breaker, Id recommend using that to turn pump on/off, rather than the breaker. Open the door and inspect for debris with a mirror and flashlight. Any tips on getting the cover off to get to the capacitor (after removing the two screws)? If there is air in the basket it hums away loudly and sucks great to prime and fill the basket (the saltwater thing even appears to be working). Hi Craig, could be a clogged filter, needing a flush out and perhaps a filter soak in DE Filter Cleaner. Its likely good advice you are getting. Hi Lou, I call that surging, and when a pump does that, and the water level (in the pool) is good, and a stuck skimmer weir is not causing the problem, I would check for an air leak in front of the pump a small void before the impeller that is pulling air in. Anyone have similar problems or have an idea what we r doing wrong? Missing push-pull valve o-rings, DE powder getting inside of the grids however thats something notable and the fact that it only does it on Low Speed, also unique. Next time it happens, check power on the timeclock, or inspect the motor, looking thru the visual motor check window (again, only on Intermatic clocks), if no power is getting to the clock, replace the breaker, and/or wiring. I shut it down again before the problem got worse. Fingers crossed it is not that! The box is reading no water flow and psi is just above 0. Didnt I switched it off properly? Inspect the pipe/union connections on the suction side for loose connections or damaged pipes. Some pumps are stronger than some hose, so check to see if the hose is not collapsing under the suction, during the issue. If you get no response from your Hayward pool pump when you flip the switch, first verify the terminal board connections match the wiring diagram on the motor data plate label. Hi Shannon, assuming that your pump is single speed (not dual speed or variable speed), it runs at a constant 3450 RPM, and is not possible to run at a lower speed. Let everything dry and put the pump on again and it just hums. They disparate as they move through the pool. Without seeing the union and setup, it is hard to say what is causing it but check for warping of the nut. If I shut the pump off for a little while and put it back on it repeats the same thing over and over, strong at first for about 5 minutes then weak. Then after it cools Im able to spin the shaft and it starts again. If theres no power at the switch/timer, go back further to the breaker. I took apart the impeller and didnt see anything that could cause a problem. When I try to turn on high speed it sounds like its jamming and then the breaker trips. When I touch any other speed button, nothing happens. Another possible cause is that the impeller is clogged with very small debris. but the digital display panel wont light up, does the propane need to be connected and turned on to make the display panel work?? I let the pump cool down, then reset the thermal switch and it runs for another hour and shuts off again.The wiring is the same and it doesnt trip the breaker switch. The electrician also installed w new capacitors on the pump and still same problem. Can u shed any light on what might be the culprit? So, I dont think you can use this motor, (sorry), unless you are able to add another 110V wire, and run both connected wires from a Double pole breaker. Give the cell an acid soak and it should clear the blockage. Could also be a loose wire connection, the power wires. I turned the gas off to it. If that doesnt solve the problem, then work through the steps below. I have an above ground 18,000gal poola Hayward SP1580X15 Power-Flo LX 1 1/2 HP pump purchased May 2017. "wordCount": "1009",
Below is the troubleshooting guide for Hayward pool heater error codes. *new pool owner of a big above ground pool* hello I bought a home it came with a pool the pump says Hayward. If you have trouble getting past this, an electrician may be a good call to make. Hello, we have a 2 speed Hayward Tgistar pump it just stopped running, I have east the breakers both at the controller and on the main panel, the pump is hot to the touch and will restart after about two minutes then shutdown again. When it comes to troubleshooting Hayward pool heater error codes, theres not too much difference between the problem solving process for other gas-fired heaters, made by Jandy, Pentair or Raypak. Ive done the reset and it still showing 4300. However this is not correct operation. This is a brand new pump out of the box that was installed and the inlet is drawing water in and filling basket and the outlet is discharging water but it just trips the breaker everytime. The Pool is a Roman 23 in ground. Hello. "@type": "Person",
Hi Davy, my pump is on a timer and will occasionally fail to turn on in the morning. 3. Also, make sure you plug in the cell all the way. Second most common air leak on a Super Pump would be the incoming pipe fitting. On Jandy valves, the spurt may be from the lid, or from the center of the lid around the stem, from a broken or missing grease cap (grey valves), or from a crack/damage. If it does make a hum or buzz sound, it could be a bad capacitor, the black cylinder at 9 oclock, in the rear of the motor. Just installed a replacement Super Pump and realized a point that may help others as they install. Any idea of the problem?? I have a Hayward sp 2603 vsp pump which is a year old has been working fine but 2 days ago I turned it on it ran about 1 minute, it cut off and on the display it says error code 11 and it will not run. Water began flowing out the pump motor and it tripped the gfci. I just replaced my pool pump motor because it was really loud and i figured it was the bearings. I closed the pool for winter. So my Hayward melted the whole left sided plastic shrouds. To reset your average salt level, turn the unit to OFF and then back to AUTO. The burnt odor is not a good sign a new motor may be needed soon! https://www.facebook.com/inyopoolsFOLLOW us on TWITTER! On high it seems fine. I can turn the temperature up but not down. If it is a 15amp breaker, but the pump wants 9amps and the aquatrol wants 7 amps, (for example, made-up numbers) thats a total of 16amps, too much. It is being practiced by thousands of pool owners just like you. Even with the cells reverse polarity feature, the scale will still form on the plates. fingers crossed, as we say. It is a H400FDN series. Is that a reason to replace impeller? "dateModified": "05/20/2022",
Now there is no water running from the pool to the motor basket. Hola tengo una caldera Hayward H400 PED2 durante el intento de encendido no enciende m caldera despus de 5 intentos me pone lF en la pantalla. Impeller turns from inside basket. Hi when you say it shuts down, I assume you mean that the water stops flowing? hayward blue essence troubleshootingautodrive microfiber towels. Recently replaced mortor and pump. the , . Not all horsepowers are created equal, meaning that a 1hp Hayward Super II pumps a lot more water than a 1hp Hayward Super I, or Max-Flo. Reset is immediate after error is corrected. Click Here to View Replacement Aquarite Parts 25 This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. i have an in ground pool. If recalibrating your salt level did not resolve your problem, then your cell or your PCBoard is bad and needs replacing. I have a Hayward Ultra Pro LX pump. Be sure though, that the motor has plenty of air flow, and the air flow vents are not blocked, and that incoming voltage is not too high or too low. Tighten in a Pattern (tighten up the bolts in a N, S, E, W, or 12, 6, 9, 3 pattern). If it is on low it works properly. Hi Doug, could be a bad breaker, or bad wiring between the pump and breaker. Please tell me if this is normal or do I need to change anything? HI Bernard, sounds like it could have cavitation, or a pipe diameter that is too small but pipe is the same. We also a sense and dispense for pool chemistry that sometimes has a ph feeder timeout error code.could this have something to do with the pool pump running off the scheduled time? Check all wires, to be sure that the metal ends of wires are not touching any metal ends of the motor housing, or contacting other wire metal ends. Have had it for 4-5 years and have had no issues. Hi Rob, normally sunshine will not cause a motor to overheat, but if it is having other internal issues generating heat, it could push it over the limit. Another check to do is to place the multiport valve on recirculate, which bypasses the filter, and will let you know for sure that the problem is in the filter sand. Seemed to be operating fine and I was vacuuming pool and lost suction. Is this the problem and should I get i checked or just replace it? If the blower prover switch opens during the postpurge cycle (heater is not firing) the control will display the error code. Its never happened before. Vibration can also cause a similar noise. I replaced the impeller ring and noticed it Suggestions? Check that they are tight and havent come loose. Pull the motor out of the pump and turn it on briefly, to see if the noise remains. Inspect the capacitor, or have it tested, or just replace with same MFD rating shown. If the motor makes no noise at all, not even a peep, then its usually a power issue. IF not, you may remove the motor end cap (with power off) and see that the wires are connected firmly. Please let me know what can be done if anything we may be calling for info. 1.5 horse power. When iturned it back on, it ran for a few seconds, sounded funny, then shut off. Hi, motors run about 140 F when running, so they are always hot to the touch. Is there something special I need to do when first installing the motor? No power not even a humming. To break the rust, you spin the shaft, or impeller. The trick is the little plug on the electrical panel MUST be moved to either 230 (up one) or to 115 (down). We have Hayward Perflex filter parts here: https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG. Heres a link to the Hayward Heater Owners Manual, which may be helpful. Thanks. Thanks for the comment! We have a Hayward 1.5 lx. The actual unit of measurement for DE powder (lol) is a 1 lb coffee can size scoop. It worked great last year, and when i went to program it this year, it didnt work unless I switch it on and off manually. I Have an electric Hayward pool heater that comes on automatically when temperatures drop and then runs 3 or 4 hours. Step 4: Verify your pumps pressure. Hi Carl, check for an air leak in front of the pump on the suction manifold, or around the pump lid, or on around the threads of the fitting that screws into the pump. The pump has been running for 2 days. you can keep running it, while you get parts sure. But, you know whats not great? HI Sang, check the capacitor, or just replace it, they are cheap, it is the large black cylinder at 9 oclock in the rear of the motor. A local motor shop could probably fix you up for $100, if you can remove the pump, and drive it to their shop. Looking for pool parts? Make sure that the drive is bonded with the bare copper wire and all four screws are secure on the drive. in the filter. Spray off well, and soak in a 5-gal bucket, the entire Flex Tube Nest, for a number of hours, hose off again, soak for another few hours, hose off thoroughly, dunk in the pool a few times, then replace in the filter tank. The hub was leaking and had to be replaced. I calibrated the unit to 3100 ppm. Originally it appears that the arrows are just off a little, but not the case. Hi, thats strange! Check it out, it could start a fire! Currently it is at pool level. What you want is the owners manual for the heater. I have my pump to run each evening from 10:30pm to 9:30am. Hi Wilson, I cant find any info on that error message paused / valve change but it would sound like it thinks that either a filter valve or directional valve is being turned, so it has paused water flow. Since the flow seems correct, could it be blockage elsewhere? This is why we usually recommend a larger cell than the cell rating would suggest. Start up again with a fresh (Full) charge of DE powder. It happens every time. Right now I can hear the pump running hard when it is turned on, but pressure gauge shows 0. BLUE WORKS PCB Main Circuit Board Compatible with Hayward Goldline GLX "
They dont usually begin to flow like a gusher, but a steady trickle. Today two years later, same company opened pool,pump stuck and want to install another 3400vsp for $1330. Make sure that the fitting that goes into the pump has no air leaks, which is the most common air leak area. Hola Ral, Podra ser una de 4 cosas: encendedor, sensor de fuego, baja presin de gas o el tablero de control. You may be removing the wrong bolts, if you are trying to loosen the 4 bolts that attach the motor to the seal plate. Diagnosing and Troubleshooting Your Hayward Aqua Rite System - INYOPools If thats not the air leak, check the pump lid o-ring, Superpump square lid rings sometimes get twisted easily. Lots of things to check, but its either air entering the system, or an obstruction, both on the suction side of the pump, or before the impeller. Hi David, these can sometimes be tricky to seal up, you are not alone. Hi Pat, good question you can continue to use the IG pump, no problem. I had my Hayward pool/spa installed about 4 years ago. Nothing tripped. Inspect the motor shaft for any obstructions. For more in depth troubleshooting or if you need help discerning which one to replace first, we recommend calling Hayward directly. The cell is new. If I block the outflow from it, it stops clicking on and off, and runs smoothly. Hi we have a Hayward DE filter for a 2040 in ground. One thing you can attempt is a superglue repair, which I have done successfully on many multiport valves, but not on a pump body. God bless your heart! But lack of sand should not cause a leaking problem. Davy, Backwash works but not filter.. we took it apart and replaced the housing gasket, diffuser gasket and seal shaft. It DOES turn on. Hi Mike, its hard to say not knowing which control system you use. If communication between the ignition board and the display board is not established within 3 s of power-up an error will be displayed. 3 No air bubbles on my returns when not vacuuming My pool pump was running fine until I turned it off. 4. inspect capacitor, usually mounted at 9 oclock, for signs of leaking, bulging, cracking If the pump makes no noise at all, turn on power, and with a multi meter, check the power at the pump, switch/timer and breaker, the problem lies where the power dies. If i knew what make/model of pump you have, I could be more specific. Hi, might have been a small clog in the pipe. Before purchasing the new pump, I replaced the breaker just to be safe, but it is still throwing the new one. Plate appeared to be good. Or you can buy the bearings and seal, and with a set of bearing pullers you can replace your own. So, grab the opening portion with pliers, while the wrench is holding the shaft still, and turn counter clockwise, it should come off, if it breaks, a new impeller is needed, but thats rare, they usually will budge. If you can grab the bolt head underneath the pad with pliers, that could help, otherwise you can cut the bolts off using a reciprocating saw with a metal blade. We purchased a Hayward Pump SP3220EE and I need to know how What can we check. How To: Troubleshoot a Hayward AquaRite - YouTube